Difference between revisions of "D scan"

From Applied Optics Wiki
Jump to: navigation, search
(Action options / examples)
(Action options / examples)
Line 36: Line 36:
 
           tell_pos 2          // report position
 
           tell_pos 2          // report position
 
           savedata            // force save data at the end of this loop (useful for live processing scripts)
 
           savedata            // force save data at the end of this loop (useful for live processing scripts)
 +
      end
 +
 +
      action apt_scan
 +
          axis 0              // axis to move
 +
          scan -1 1 0.5      // start stop inc
 +
          restore            // return to original position at end
 
       end
 
       end

Revision as of 14:07, 7 March 2016

this is a page to list feature requests, bugs and give usage examples for d_scan.


Feature requests

  • check if files exist - request permission to overwrite, action option to turn off checking
  • save option to force saving in actions for live data plotting options for long scans
  • general scan option, with hardware type select
  • scope to switch to summed mode if averaging is on, then switch back to continuous at end.

Completed tasks

  • save scope mode (seg, RT etc) and number of avgs, number of segs to scope meta data file

Bugs

Action options / examples

     action webcam 
         camera 1              //camera ID no
         resolution 1280 720   // resolution to open camera with
         grab                  // saves a frame from the camera
         display               // displays a frame from the camera 
     end 
     action scope 
         channels F1,F3       // use name of channel you want separated by commas
         ip 128.243.74.74     // IP address of scope
     end
     action a2d 
         channel 0           // channel to grab
         range 2             // this is card specific voltage range use comedi test to find ranges ./usr/bin/comedi_test
         n_samples 1         // samples to grab
     end
     action mirror_pbp       // mirror scan point by point
         axis 0 -1 1 .1      // axis number, start, stop, increment
         tell_pos 2          // report position
         savedata            // force save data at the end of this loop (useful for live processing scripts)
     end
     action apt_scan
         axis 0              // axis to move
         scan -1 1 0.5       // start stop inc
         restore             // return to original position at end
     end