https://optics.eee.nottingham.ac.uk/w/index.php?title=Smart_Textile_Based_Optical_Sensing_for_Health_Care&feed=atom&action=history
Smart Textile Based Optical Sensing for Health Care - Revision history
2024-03-28T20:32:19Z
Revision history for this page on the wiki
MediaWiki 1.27.1
https://optics.eee.nottingham.ac.uk/w/index.php?title=Smart_Textile_Based_Optical_Sensing_for_Health_Care&diff=3955&oldid=prev
Hattan Ballaji at 13:46, 22 July 2019
2019-07-22T13:46:37Z
<p></p>
<table class="diff diff-contentalign-left" data-mw="interface">
<col class='diff-marker' />
<col class='diff-content' />
<col class='diff-marker' />
<col class='diff-content' />
<tr style='vertical-align: top;' lang='en'>
<td colspan='2' style="background-color: white; color:black; text-align: center;">← Older revision</td>
<td colspan='2' style="background-color: white; color:black; text-align: center;">Revision as of 13:46, 22 July 2019</td>
</tr><tr><td colspan="2" class="diff-lineno" id="mw-diff-left-l1" >Line 1:</td>
<td colspan="2" class="diff-lineno">Line 1:</td></tr>
<tr><td class='diff-marker'>−</td><td style="color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;"><div><del style="font-weight: bold; text-decoration: none;">'''Smart Textile Based Optical Sensing for Health Care</del></div></td><td colspan="2"> </td></tr>
<tr><td class='diff-marker'>−</td><td style="color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;"><div><del style="font-weight: bold; text-decoration: none;">'''</del></div></td><td colspan="2"> </td></tr>
<tr><td class='diff-marker'>−</td><td style="color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;"><div><del style="font-weight: bold; text-decoration: none;">----</del></div></td><td colspan="2"> </td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"></td><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"></td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"></td><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"></td></tr>
</table>
Hattan Ballaji
https://optics.eee.nottingham.ac.uk/w/index.php?title=Smart_Textile_Based_Optical_Sensing_for_Health_Care&diff=3954&oldid=prev
Hattan Ballaji at 13:46, 22 July 2019
2019-07-22T13:46:15Z
<p></p>
<table class="diff diff-contentalign-left" data-mw="interface">
<col class='diff-marker' />
<col class='diff-content' />
<col class='diff-marker' />
<col class='diff-content' />
<tr style='vertical-align: top;' lang='en'>
<td colspan='2' style="background-color: white; color:black; text-align: center;">← Older revision</td>
<td colspan='2' style="background-color: white; color:black; text-align: center;">Revision as of 13:46, 22 July 2019</td>
</tr><tr><td colspan="2" class="diff-lineno" id="mw-diff-left-l2" >Line 2:</td>
<td colspan="2" class="diff-lineno">Line 2:</td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"><div>'''</div></td><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"><div>'''</div></td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"><div>----</div></td><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"><div>----</div></td></tr>
<tr><td colspan="2"> </td><td class='diff-marker'>+</td><td style="color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div><ins style="font-weight: bold; text-decoration: none;"></ins></div></td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"></td><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"></td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"><div>'''Introduction'''  </div></td><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"><div>'''Introduction'''  </div></td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"></td><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"></td></tr>
<tr><td class='diff-marker'>−</td><td style="color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;"><div>• Photoplethysmograph (PPG) technology is used extensively in applied optics sensors that are most commonly found in medical devices. The PPG technique can be implemented in transmission and reflection modes<del class="diffchange diffchange-inline">, </del>and provides information about blood volume changes, the heart rate (HR) by using one wavelength and can also be used to monitor the oxygen saturation (SpO2) levels by using two wavelengths.</div></td><td class='diff-marker'>+</td><td style="color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div>• Photoplethysmograph (PPG) technology is used extensively in applied optics sensors that are most commonly found in medical devices. The PPG technique can be implemented in transmission and reflection modes and provides information about blood volume changes, the heart rate (HR) by using one wavelength and can also be used to monitor the oxygen saturation (SpO2) levels by using two wavelengths.</div></td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"></td><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"></td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"><div>• Capillary refill time (CRT) is Recording the time that taken for the skin to regain its colour back after blanching.</div></td><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"><div>• Capillary refill time (CRT) is Recording the time that taken for the skin to regain its colour back after blanching.</div></td></tr>
<tr><td colspan="2" class="diff-lineno" id="mw-diff-left-l11" >Line 11:</td>
<td colspan="2" class="diff-lineno">Line 12:</td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"></td><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"></td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"></td><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"></td></tr>
<tr><td class='diff-marker'>−</td><td style="color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;"><div>'''<del class="diffchange diffchange-inline">Working Principle </del></div></td><td class='diff-marker'>+</td><td style="color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div>'''<ins class="diffchange diffchange-inline">Background </ins></div></td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"><div>'''</div></td><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"><div>'''</div></td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"></td><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"></td></tr>
</table>
Hattan Ballaji
https://optics.eee.nottingham.ac.uk/w/index.php?title=Smart_Textile_Based_Optical_Sensing_for_Health_Care&diff=3953&oldid=prev
Hattan Ballaji at 13:45, 22 July 2019
2019-07-22T13:45:14Z
<p></p>
<table class="diff diff-contentalign-left" data-mw="interface">
<col class='diff-marker' />
<col class='diff-content' />
<col class='diff-marker' />
<col class='diff-content' />
<tr style='vertical-align: top;' lang='en'>
<td colspan='2' style="background-color: white; color:black; text-align: center;">← Older revision</td>
<td colspan='2' style="background-color: white; color:black; text-align: center;">Revision as of 13:45, 22 July 2019</td>
</tr><tr><td colspan="2" class="diff-lineno" id="mw-diff-left-l15" >Line 15:</td>
<td colspan="2" class="diff-lineno">Line 15:</td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"></td><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"></td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"><div>• Red and IR wavelength lights are needed in order to operate the SpO2 devices because the level of absorption for both lights varies for oxyhaemoglobin (HbO2) and deoxyhaemoglobin (Hb) blood. The red and IR PPG signals of pulse oximeter devices are used to calculate the absorbance ratio (R) that can be calculated by Equation 1.1.</div></td><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"><div>• Red and IR wavelength lights are needed in order to operate the SpO2 devices because the level of absorption for both lights varies for oxyhaemoglobin (HbO2) and deoxyhaemoglobin (Hb) blood. The red and IR PPG signals of pulse oximeter devices are used to calculate the absorbance ratio (R) that can be calculated by Equation 1.1.</div></td></tr>
<tr><td class='diff-marker'>−</td><td style="color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;"><div><del style="font-weight: bold; text-decoration: none;"></del></div></td><td colspan="2"> </td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"></td><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"></td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"><div>                                               Equation 1.1: R=  ((Red_AC)/(Red_DC ))⁄((IR_AC)/(IR_DC ))</div></td><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"><div>                                               Equation 1.1: R=  ((Red_AC)/(Red_DC ))⁄((IR_AC)/(IR_DC ))</div></td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"></td><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"></td></tr>
<tr><td class='diff-marker'>−</td><td style="color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;"><div><del class="diffchange diffchange-inline">IAC and IDC for red and IR are the AC and DC levels of each. </del>The ratio calibration between red and IR can be measured by Equation 1.2 in order to calculate the SpO2.</div></td><td class='diff-marker'>+</td><td style="color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div>The ratio calibration between red and IR can be measured by Equation 1.2 in order to calculate the SpO2.</div></td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"></td><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"></td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"><div>                                                           Equation 1.2: % SpO2 = 110 – 25 R  </div></td><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"><div>                                                           Equation 1.2: % SpO2 = 110 – 25 R  </div></td></tr>
</table>
Hattan Ballaji
https://optics.eee.nottingham.ac.uk/w/index.php?title=Smart_Textile_Based_Optical_Sensing_for_Health_Care&diff=3952&oldid=prev
Hattan Ballaji at 13:43, 22 July 2019
2019-07-22T13:43:55Z
<p></p>
<table class="diff diff-contentalign-left" data-mw="interface">
<col class='diff-marker' />
<col class='diff-content' />
<col class='diff-marker' />
<col class='diff-content' />
<tr style='vertical-align: top;' lang='en'>
<td colspan='2' style="background-color: white; color:black; text-align: center;">← Older revision</td>
<td colspan='2' style="background-color: white; color:black; text-align: center;">Revision as of 13:43, 22 July 2019</td>
</tr><tr><td colspan="2" class="diff-lineno" id="mw-diff-left-l17" >Line 17:</td>
<td colspan="2" class="diff-lineno">Line 17:</td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"></td><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"></td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"></td><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"></td></tr>
<tr><td class='diff-marker'>−</td><td style="color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;"><div><del class="diffchange diffchange-inline">                            </del>Equation 1.1: R=  ((Red_AC)/(Red_DC ))⁄((IR_AC)/(IR_DC ))</div></td><td class='diff-marker'>+</td><td style="color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div><ins class="diffchange diffchange-inline">                                              </ins>Equation 1.1: R=  ((Red_AC)/(Red_DC ))⁄((IR_AC)/(IR_DC ))</div></td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"></td><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"></td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"><div>IAC and IDC for red and IR are the AC and DC levels of each. The ratio calibration between red and IR can be measured by Equation 1.2 in order to calculate the SpO2.</div></td><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"><div>IAC and IDC for red and IR are the AC and DC levels of each. The ratio calibration between red and IR can be measured by Equation 1.2 in order to calculate the SpO2.</div></td></tr>
</table>
Hattan Ballaji
https://optics.eee.nottingham.ac.uk/w/index.php?title=Smart_Textile_Based_Optical_Sensing_for_Health_Care&diff=3951&oldid=prev
Hattan Ballaji at 13:43, 22 July 2019
2019-07-22T13:43:38Z
<p></p>
<table class="diff diff-contentalign-left" data-mw="interface">
<col class='diff-marker' />
<col class='diff-content' />
<col class='diff-marker' />
<col class='diff-content' />
<tr style='vertical-align: top;' lang='en'>
<td colspan='2' style="background-color: white; color:black; text-align: center;">← Older revision</td>
<td colspan='2' style="background-color: white; color:black; text-align: center;">Revision as of 13:43, 22 July 2019</td>
</tr><tr><td colspan="2" class="diff-lineno" id="mw-diff-left-l16" >Line 16:</td>
<td colspan="2" class="diff-lineno">Line 16:</td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"><div>• Red and IR wavelength lights are needed in order to operate the SpO2 devices because the level of absorption for both lights varies for oxyhaemoglobin (HbO2) and deoxyhaemoglobin (Hb) blood. The red and IR PPG signals of pulse oximeter devices are used to calculate the absorbance ratio (R) that can be calculated by Equation 1.1.</div></td><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"><div>• Red and IR wavelength lights are needed in order to operate the SpO2 devices because the level of absorption for both lights varies for oxyhaemoglobin (HbO2) and deoxyhaemoglobin (Hb) blood. The red and IR PPG signals of pulse oximeter devices are used to calculate the absorbance ratio (R) that can be calculated by Equation 1.1.</div></td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"></td><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"></td></tr>
<tr><td class='diff-marker'>−</td><td style="color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;"><div>                             Equation 1.1: R=  ((<del class="diffchange diffchange-inline">Red〖 I〗_AC</del>)/(<del class="diffchange diffchange-inline">Red〖 I〗_DC </del>))⁄((<del class="diffchange diffchange-inline">IR〖 I〗_AC</del>)/(<del class="diffchange diffchange-inline">IR〖 I〗_DC </del>))</div></td><td class='diff-marker'>+</td><td style="color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div> </div></td></tr>
<tr><td colspan="2"> </td><td class='diff-marker'>+</td><td style="color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div>                             Equation 1.1: R=  ((<ins class="diffchange diffchange-inline">Red_AC</ins>)/(<ins class="diffchange diffchange-inline">Red_DC </ins>))⁄((<ins class="diffchange diffchange-inline">IR_AC</ins>)/(<ins class="diffchange diffchange-inline">IR_DC </ins>))</div></td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"></td><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"></td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"><div>IAC and IDC for red and IR are the AC and DC levels of each. The ratio calibration between red and IR can be measured by Equation 1.2 in order to calculate the SpO2.</div></td><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"><div>IAC and IDC for red and IR are the AC and DC levels of each. The ratio calibration between red and IR can be measured by Equation 1.2 in order to calculate the SpO2.</div></td></tr>
</table>
Hattan Ballaji
https://optics.eee.nottingham.ac.uk/w/index.php?title=Smart_Textile_Based_Optical_Sensing_for_Health_Care&diff=3950&oldid=prev
Hattan Ballaji at 13:41, 22 July 2019
2019-07-22T13:41:03Z
<p></p>
<table class="diff diff-contentalign-left" data-mw="interface">
<col class='diff-marker' />
<col class='diff-content' />
<col class='diff-marker' />
<col class='diff-content' />
<tr style='vertical-align: top;' lang='en'>
<td colspan='2' style="background-color: white; color:black; text-align: center;">← Older revision</td>
<td colspan='2' style="background-color: white; color:black; text-align: center;">Revision as of 13:41, 22 July 2019</td>
</tr><tr><td colspan="2" class="diff-lineno" id="mw-diff-left-l15" >Line 15:</td>
<td colspan="2" class="diff-lineno">Line 15:</td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"></td><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"></td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"><div>• Red and IR wavelength lights are needed in order to operate the SpO2 devices because the level of absorption for both lights varies for oxyhaemoglobin (HbO2) and deoxyhaemoglobin (Hb) blood. The red and IR PPG signals of pulse oximeter devices are used to calculate the absorbance ratio (R) that can be calculated by Equation 1.1.</div></td><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"><div>• Red and IR wavelength lights are needed in order to operate the SpO2 devices because the level of absorption for both lights varies for oxyhaemoglobin (HbO2) and deoxyhaemoglobin (Hb) blood. The red and IR PPG signals of pulse oximeter devices are used to calculate the absorbance ratio (R) that can be calculated by Equation 1.1.</div></td></tr>
<tr><td class='diff-marker'>−</td><td style="color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;"><div>Equation 1.1: R=  ((Red〖 I〗_AC)/(Red〖 I〗_DC ))⁄((IR〖 I〗_AC)/(IR〖 I〗_DC ))</div></td><td class='diff-marker'>+</td><td style="color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div> </div></td></tr>
<tr><td colspan="2"> </td><td class='diff-marker'>+</td><td style="color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div><ins class="diffchange diffchange-inline">                            </ins>Equation 1.1: R=  ((Red〖 I〗_AC)/(Red〖 I〗_DC ))⁄((IR〖 I〗_AC)/(IR〖 I〗_DC ))</div></td></tr>
<tr><td colspan="2"> </td><td class='diff-marker'>+</td><td style="color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div> </div></td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"><div>IAC and IDC for red and IR are the AC and DC levels of each. The ratio calibration between red and IR can be measured by Equation 1.2 in order to calculate the SpO2.</div></td><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"><div>IAC and IDC for red and IR are the AC and DC levels of each. The ratio calibration between red and IR can be measured by Equation 1.2 in order to calculate the SpO2.</div></td></tr>
<tr><td class='diff-marker'>−</td><td style="color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;"><div>Equation 1.2: % SpO2 = 110 – 25 R  </div></td><td class='diff-marker'>+</td><td style="color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div> </div></td></tr>
<tr><td colspan="2"> </td><td class='diff-marker'>+</td><td style="color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div><ins class="diffchange diffchange-inline">                                                          </ins>Equation 1.2: % SpO2 = 110 – 25 R  </div></td></tr>
<tr><td colspan="2"> </td><td class='diff-marker'>+</td><td style="color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div> </div></td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"></td><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"></td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"><div>• Measuring the CRT (colour change) by detecting the reflected light from the skin also while measuring the contact pressure using Fibre Bragg Grating (FBG).  </div></td><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"><div>• Measuring the CRT (colour change) by detecting the reflected light from the skin also while measuring the contact pressure using Fibre Bragg Grating (FBG).  </div></td></tr>
<tr><td colspan="2" class="diff-lineno" id="mw-diff-left-l25" >Line 25:</td>
<td colspan="2" class="diff-lineno">Line 29:</td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"><div>'''</div></td><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"><div>'''</div></td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"></td><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"></td></tr>
<tr><td class='diff-marker'>−</td><td style="color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #ffe49c; vertical-align: top; white-space: pre-wrap;"><div>• Develop a multi-channel textile-based optical fibre measurement system for detecting of the PPG,  </div></td><td class='diff-marker'>+</td><td style="color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div>• Develop a multi-channel textile-based optical fibre measurement system for detecting of the PPG,</div></td></tr>
<tr><td colspan="2"> </td><td class='diff-marker'>+</td><td style="color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div><ins class="diffchange diffchange-inline"> </ins></div></td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"><div>• Monitoring the SpO2 using two different wavelengths (660nm and 850nm),  </div></td><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"><div>• Monitoring the SpO2 using two different wavelengths (660nm and 850nm),  </div></td></tr>
<tr><td colspan="2"> </td><td class='diff-marker'>+</td><td style="color:black; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;"><div><ins style="font-weight: bold; text-decoration: none;"></ins></div></td></tr>
<tr><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"><div>• Measure the CRT and the contact pressure.</div></td><td class='diff-marker'> </td><td style="background-color: #f9f9f9; color: #333333; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #e6e6e6; vertical-align: top; white-space: pre-wrap;"><div>• Measure the CRT and the contact pressure.</div></td></tr>
</table>
Hattan Ballaji
https://optics.eee.nottingham.ac.uk/w/index.php?title=Smart_Textile_Based_Optical_Sensing_for_Health_Care&diff=3949&oldid=prev
Hattan Ballaji: Created page with "'''Smart Textile Based Optical Sensing for Health Care ''' ---- '''Introduction''' • Photoplethysmograph (PPG) technology is used extensively in applied optics sensors th..."
2019-07-22T13:40:03Z
<p>Created page with "'''Smart Textile Based Optical Sensing for Health Care ''' ---- '''Introduction''' • Photoplethysmograph (PPG) technology is used extensively in applied optics sensors th..."</p>
<p><b>New page</b></p><div>'''Smart Textile Based Optical Sensing for Health Care<br />
'''<br />
----<br />
<br />
'''Introduction''' <br />
<br />
• Photoplethysmograph (PPG) technology is used extensively in applied optics sensors that are most commonly found in medical devices. The PPG technique can be implemented in transmission and reflection modes, and provides information about blood volume changes, the heart rate (HR) by using one wavelength and can also be used to monitor the oxygen saturation (SpO2) levels by using two wavelengths.<br />
<br />
• Capillary refill time (CRT) is Recording the time that taken for the skin to regain its colour back after blanching.<br />
<br />
<br />
<br />
'''Working Principle <br />
'''<br />
<br />
• Red and IR wavelength lights are needed in order to operate the SpO2 devices because the level of absorption for both lights varies for oxyhaemoglobin (HbO2) and deoxyhaemoglobin (Hb) blood. The red and IR PPG signals of pulse oximeter devices are used to calculate the absorbance ratio (R) that can be calculated by Equation 1.1.<br />
Equation 1.1: R= ((Red〖 I〗_AC)/(Red〖 I〗_DC ))⁄((IR〖 I〗_AC)/(IR〖 I〗_DC ))<br />
IAC and IDC for red and IR are the AC and DC levels of each. The ratio calibration between red and IR can be measured by Equation 1.2 in order to calculate the SpO2.<br />
Equation 1.2: % SpO2 = 110 – 25 R <br />
<br />
• Measuring the CRT (colour change) by detecting the reflected light from the skin also while measuring the contact pressure using Fibre Bragg Grating (FBG). <br />
<br />
<br />
'''Project aim <br />
'''<br />
<br />
• Develop a multi-channel textile-based optical fibre measurement system for detecting of the PPG, <br />
• Monitoring the SpO2 using two different wavelengths (660nm and 850nm), <br />
• Measure the CRT and the contact pressure.</div>
Hattan Ballaji