A quick test to determine the spectral responsivity of the 0.35um process we use quite a lot in this department.
+
Results from an experiment to determine the spectral responsivity of the 0.35um process we use quite a lot in this department. May be useful to other users of this process.
  
 
Experiment was conducted on SKED1. 30kOhm load, using 8 hi-power LEDs.
 
Experiment was conducted on SKED1. 30kOhm load, using 8 hi-power LEDs.
 +
 
<gallery>
 
<gallery>
File:Sked1_R.jpg|Responsivity and Quantum Efficiency
+
File:Sked1_R.png|Responsivity and Quantum Efficiency
 
</gallery>
 
</gallery>
  
 
+
There is no data from the C35 datasheet, but the related opto process gives responsivity data, and this data is overlaid on the SKED1 results (in red). The dotted line is the actual response of the optoC35 response, with a 7th order polynomial fit in the solid line. The blue line is the response of the C35 process as measured using SKED1.
 
 
There is no data from the C35 datasheet, but the opto process gives responsivity data, and this data is overlaid on the results (in red). The dotted line is the actual response of the optoC35 response, with a 7th order polynomial fit in the solid line. The blue line is the response of the C35 process as measured using SKED1.
 

Revision as of 14:20, 18 November 2013

Results from an experiment to determine the spectral responsivity of the 0.35um process we use quite a lot in this department. May be useful to other users of this process.

Experiment was conducted on SKED1. 30kOhm load, using 8 hi-power LEDs.

There is no data from the C35 datasheet, but the related opto process gives responsivity data, and this data is overlaid on the SKED1 results (in red). The dotted line is the actual response of the optoC35 response, with a 7th order polynomial fit in the solid line. The blue line is the response of the C35 process as measured using SKED1.