Difference between revisions of "AO resources"
Line 1: | Line 1: | ||
− | + | Applied Optics Group Resources | |
This is a list of resources for use within the Applied Optics Group. This can include: | This is a list of resources for use within the Applied Optics Group. This can include: | ||
Line 12: | Line 12: | ||
I (Steve) will make a start on this of the things I know about, and some of the things I vaguely know about. Please correct errors and omissions. | I (Steve) will make a start on this of the things I know about, and some of the things I vaguely know about. Please correct errors and omissions. | ||
− | + | = Internal Facilities = | |
− | + | == ASOPs dual fs laser system == | |
TBA | TBA | ||
− | + | == Fab Lab == | |
Facility for fabricating samples. You need training to use any of this facility - if you aren't already using it please don't help yourself. Ask someone to show you around and train you on the kit you are interested in. | Facility for fabricating samples. You need training to use any of this facility - if you aren't already using it please don't help yourself. Ask someone to show you around and train you on the kit you are interested in. | ||
Line 41: | Line 41: | ||
When using it please complete the log books (and indicate your supervisor). | When using it please complete the log books (and indicate your supervisor). | ||
− | + | == Soldering and minor metalworking == | |
Pillar drill (fairly crap), small bench vice, hand files, hacksaw, clamps etc. | Pillar drill (fairly crap), small bench vice, hand files, hacksaw, clamps etc. | ||
Line 60: | Line 60: | ||
** Switch everything off at the plug after you've used it - especially important for the soldering iron. | ** Switch everything off at the plug after you've used it - especially important for the soldering iron. | ||
− | + | == O-SAM == | |
'''Description needs completing''' | '''Description needs completing''' | ||
Line 72: | Line 72: | ||
* ''Extra info:'' | * ''Extra info:'' | ||
− | + | == Scanning tank == | |
* Ultrasonic scanning tank | * Ultrasonic scanning tank | ||
Line 87: | Line 87: | ||
− | + | = Equipment and Instruments = | |
− | + | == Posh Zeiss Microscope == | |
'''Description needs completing''' | '''Description needs completing''' | ||
Line 99: | Line 99: | ||
* ''Extra info:'' | * ''Extra info:'' | ||
− | + | == Old Olympus Microscope == | |
Olympus optical microscope, fairly old, but quite good. Optical only - although has a port for attaching a camera, think it's some sort of old Olympus manual SLR fitting. Manual focus and manual x-y. Illuminates top and bottom, has some ND filters, facilities for phase contrast, Nomarski prism. | Olympus optical microscope, fairly old, but quite good. Optical only - although has a port for attaching a camera, think it's some sort of old Olympus manual SLR fitting. Manual focus and manual x-y. Illuminates top and bottom, has some ND filters, facilities for phase contrast, Nomarski prism. | ||
Line 110: | Line 110: | ||
** Put the eye-piece covers back on, and (after the microscope has cooled down) replace the dust cover. | ** Put the eye-piece covers back on, and (after the microscope has cooled down) replace the dust cover. | ||
− | + | == Atomic Force Microscope (AFM) == | |
'''Description needs completing''' | '''Description needs completing''' | ||
Line 118: | Line 118: | ||
* ''Extra info:'' | * ''Extra info:'' | ||
− | + | == Polytec Laser Vibrometer == | |
[http://www.polytec.com/eur/158_421.asp Polytec single-point vibrometer] comprising: | [http://www.polytec.com/eur/158_421.asp Polytec single-point vibrometer] comprising: | ||
Line 137: | Line 137: | ||
** Laser is class 2 (He:Ne) <1mW but don't look into the beam and follow all the usual precautions | ** Laser is class 2 (He:Ne) <1mW but don't look into the beam and follow all the usual precautions | ||
− | + | == Agilent 4GHz Oscilloscope == | |
[http://www.home.agilent.com/agilent/product.jspx?nid=-536902755.536908563.00&cc=AU&lc=eng Agilent Infiniium 80404B Oscilloscope] | [http://www.home.agilent.com/agilent/product.jspx?nid=-536902755.536908563.00&cc=AU&lc=eng Agilent Infiniium 80404B Oscilloscope] | ||
Line 157: | Line 157: | ||
***Linux: see [[Experimental PC#Scope (and AFG) utilities|this wiki page]] about installing ''agetwf'' (or install ''c_scan'' for more complex acquisition) | ***Linux: see [[Experimental PC#Scope (and AFG) utilities|this wiki page]] about installing ''agetwf'' (or install ''c_scan'' for more complex acquisition) | ||
− | + | == Tektronix MSO4034 Mixed Signal Oscilloscope == | |
[http://www.tek.com/products/oscilloscopes/mso4000/ Tektronix MSO4034 mixed signal oscilloscope] | [http://www.tek.com/products/oscilloscopes/mso4000/ Tektronix MSO4034 mixed signal oscilloscope] | ||
Line 175: | Line 175: | ||
***Linux: see [[Experimental PC#Scope (and AFG) utilities|this wiki page]] about installing ''tgetwf'' (or install ''c_scan'' for more complex acquisition) | ***Linux: see [[Experimental PC#Scope (and AFG) utilities|this wiki page]] about installing ''tgetwf'' (or install ''c_scan'' for more complex acquisition) | ||
− | + | == Laser Beam Profiler == | |
[http://www.newport.com/Laser-Beam-Profiler/318103/1033/catalog.aspx Newport LBP-2-USB laser beam profiler] | [http://www.newport.com/Laser-Beam-Profiler/318103/1033/catalog.aspx Newport LBP-2-USB laser beam profiler] | ||
Line 190: | Line 190: | ||
*** Plug USB dongle into PC | *** Plug USB dongle into PC | ||
− | + | == Optical (Thermal) Power Meter == | |
[http://www.lambdaphoto.co.uk/xlp12 Gentec XLP-12] Thermopile-based optical power meter | [http://www.lambdaphoto.co.uk/xlp12 Gentec XLP-12] Thermopile-based optical power meter | ||
Line 200: | Line 200: | ||
** Works fine with mode-locked (e.g. femtosecond), Q-switched (Nd:YAG) and CW lasers (long time constant) | ** Works fine with mode-locked (e.g. femtosecond), Q-switched (Nd:YAG) and CW lasers (long time constant) | ||
− | + | == High Frequency Lock-in Amplifier == | |
[http://www.thinksrs.com/products/SR844.htm SR844 high frequency lock-in amplifier] | [http://www.thinksrs.com/products/SR844.htm SR844 high frequency lock-in amplifier] | ||
Line 217: | Line 217: | ||
* ''Extra info:'' | * ''Extra info:'' | ||
− | + | == Ultrasonic Pulser-Receiver == | |
[http://www.olympusndt.com/en/5072pr/ Olympus (formerly Panametrics) 5072PR Ultrasonic Pulser-Receiver] | [http://www.olympusndt.com/en/5072pr/ Olympus (formerly Panametrics) 5072PR Ultrasonic Pulser-Receiver] | ||
Line 228: | Line 228: | ||
* ''Extra info:'' | * ''Extra info:'' | ||
− | + | == Dell 12" Laptop == | |
[http://www.dell.com/downloads/emea/products/latit/D430_specs%20_sheet.pdf Dell Latitude D430 12" Laptop] | [http://www.dell.com/downloads/emea/products/latit/D430_specs%20_sheet.pdf Dell Latitude D430 12" Laptop] | ||
Line 247: | Line 247: | ||
** Set up with static (optics) IP on ethernet, and DHCP (roaming/UoN) on WiFi | ** Set up with static (optics) IP on ethernet, and DHCP (roaming/UoN) on WiFi | ||
− | + | == Apple Macbook Laptop - cracked screen == | |
Apple Macbook laptop, 1.8GHz Core 2 Duo processor. Has a cracked screen, making it pretty much unusable as a laptop. Now pensioned off to desktop duties. | Apple Macbook laptop, 1.8GHz Core 2 Duo processor. Has a cracked screen, making it pretty much unusable as a laptop. Now pensioned off to desktop duties. | ||
Line 258: | Line 258: | ||
* ''Contact:'' [[Steve Sharples]] | * ''Contact:'' [[Steve Sharples]] | ||
− | + | = Local Expertise = | |
This section to be filled in another day. | This section to be filled in another day. | ||
− | + | = External Facilities = | |
− | + | == Ground floor workshop == | |
− | + | == Physics fabrication and coating facilities == | |
− | |||
− | |||
− | |||
− | |||
Talk to [[Teti Stratoudaki]] or Jing Zhang | Talk to [[Teti Stratoudaki]] or Jing Zhang |
Revision as of 08:11, 5 May 2010
Applied Optics Group Resources
This is a list of resources for use within the Applied Optics Group. This can include:
- Internal facilities
- Equipment and instruments (bought on shared funding e.g. SRIF)
- Local expertise
- External facilities (that members of the Applied Optics Group use)
Some of the facilities are "home-built" experiments - cutting edge facilities that may not be available anywhere else in the world, but on the other hand may be tied up/uncalibrated/moth-balled. Others are commercial.
I (Steve) will make a start on this of the things I know about, and some of the things I vaguely know about. Please correct errors and omissions.
Contents
- 1 Internal Facilities
- 2 Equipment and Instruments
- 2.1 Posh Zeiss Microscope
- 2.2 Old Olympus Microscope
- 2.3 Atomic Force Microscope (AFM)
- 2.4 Polytec Laser Vibrometer
- 2.5 Agilent 4GHz Oscilloscope
- 2.6 Tektronix MSO4034 Mixed Signal Oscilloscope
- 2.7 Laser Beam Profiler
- 2.8 Optical (Thermal) Power Meter
- 2.9 High Frequency Lock-in Amplifier
- 2.10 Ultrasonic Pulser-Receiver
- 2.11 Dell 12" Laptop
- 2.12 Apple Macbook Laptop - cracked screen
- 3 Local Expertise
- 4 External Facilities
Internal Facilities
ASOPs dual fs laser system
TBA
Fab Lab
Facility for fabricating samples. You need training to use any of this facility - if you aren't already using it please don't help yourself. Ask someone to show you around and train you on the kit you are interested in.
You also need to keep logs of everything you do in this lab.
Facilities for metal film evaporation/sputtering, photo-lithography and general chemical procedures that require working under a fume-cupboard and a clean-ish environment.
- Location: SiOS Labs
- Contact: Matt Clark or Teti Stratoudaki
!!! Please Keep Clean at all times !!!
- The Lab is equipped with:
- Edwards 306A evaporator with 6 sources
- Emitech K575XD sputter coater with 2 sources
- Carbolite oven
- Cobilt mask aligner
- Spin coater
- Decent scales
- Microscope (camera TBA)
When using it please complete the log books (and indicate your supervisor).
Soldering and minor metalworking
Pillar drill (fairly crap), small bench vice, hand files, hacksaw, clamps etc.
Temperature-controlled soldering iron
Various PSUs, signal generators and scopes - all old
Stock components (resistors, fuses, cables, wire, plugs/sockets/connectors etc)
- Location: Tower 201 (Applied Optics Main Lab)
- Contact: Steve Sharples (for missing bits of equipment)
- Extra info:
- Make sure you know what you're doing and how to operate the drill. Seek instruction if you're unsure. Don't take risks. Wear safety goggles (should be some nearby). Set the drill speed appropriately. Unplug the drill from the wall when moving the belt between pulleys. Clamp things down when drilling them (use the brush not your hands).
- Tidy up after yourself - especially bits of metal after drilling.
- Replace what you use: solder, solder wick, wire, stock components, anything.
- If you see some old equipment and notice the electrical testing label has expired, get it PAT tested in the stores - it only takes a few minutes.
- Switch everything off at the plug after you've used it - especially important for the soldering iron.
O-SAM
Description needs completing
- SRAS: surface microstructure imaging, using surface acoustic wave (SAW) velocity as contrast mechanism
- Coating thickness measurement (again using SAW velocity)
- Surface defect detection (cracks, delamination)
- Location: Tower 303 and 306 (Laser Ultrasound Labs)
- Contact: Steve Sharples (for missing bits of equipment)
- Extra info:
Scanning tank
- Ultrasonic scanning tank
- 6-axis
- 2 axes may be scanned simultaneously
- Panametrics 35MHz pulser-receiver
- Range of focused and plane beam transducers
- Agilent DSO8010A oscilloscope for acquisition
- Uses c_scan running under Linux for control and acquisition
- Location: Tower 201 (Applied Optics Main Lab)
- Contact: Steve Sharples
- Extra info:
Equipment and Instruments
Posh Zeiss Microscope
Description needs completing
PC-controlled, with eye-pieces and CCD camera. Can reportedly stitch several images together. Illuminate from above and below. Lots of fancy stuff...
- Location: iBIOS Labs, somewhere.
- Contact: Shugang Liu? Jing Zhang?
- Extra info:
Old Olympus Microscope
Olympus optical microscope, fairly old, but quite good. Optical only - although has a port for attaching a camera, think it's some sort of old Olympus manual SLR fitting. Manual focus and manual x-y. Illuminates top and bottom, has some ND filters, facilities for phase contrast, Nomarski prism.
- Location: Tower 201 (Applied Optics Main Lab)
- Contact: No-one really. Turn up and use it. If it's faulty, ask around or get it fixed yourself.
- Extra info:
- There are 2 plugs. One powers the lower lamp, the other the top lamp. Top lamp is controlled by the external box that sits next to the microscope (switch on the side, use the knob to control brightness).
- Switch the plugs off at the wall after use.
- Put the eye-piece covers back on, and (after the microscope has cooled down) replace the dust cover.
Atomic Force Microscope (AFM)
Description needs completing
- Location: iBIOS Labs, somewhere
- Contact: Shugang Liu
- Extra info:
Polytec Laser Vibrometer
Polytec single-point vibrometer comprising:
- OFV-5000 Modular Vibrometer Controller
- OFV-534 Compact Sensor Head
- VD-02 velocity decoder (DC-1.5MHz)
- DD-300 displacement decoder (50kHz-24MHz)
- Total range <1Hz - 24MHz
- Calibrated output (convert volts to actual displacement)
- Internal CCD camera so you can see what you're scanning
- Location: usually 201 on the scanning tank, sometimes SiOS
- Contact: Steve Sharples
- Extra info:
- Includes a couple of Mitutoyo objectives (x10 and x20) for very small spot size (useful for MEMs etc)
- Includes a 15" flat screen TV for the internal CCD camera
- Laser is class 2 (He:Ne) <1mW but don't look into the beam and follow all the usual precautions
Agilent 4GHz Oscilloscope
Agilent Infiniium 80404B Oscilloscope
- 4 channels
- 4GHz analogue bandwidth
- 40/20GSa/s (2/4 ch)
- Extra waveform memory (2Mpts)
- 50 Ohm inputs; 2 adapters available to convert 2 inputs to 1M Ohm.
- Matlab module
- Location: Usually one of the Laser Ultrasound Labs (303-307)
- Contact: Steve Sharples or whoever's lab it's in
- Extra info:
- Sensitive inputs: they may look like regular BNCs, but if you start shoving 10V into them you're going to end up with a very large repair bill and will probably get a bollocking. Maximum voltage is written on the scopes. Use the 1M Ohm adapters if you need to look at bigger voltages (or have a high input impedance) but even with these the range of voltages that it can cope with is limited.
- There is a Matlab module installed - I've never used it, but it might be useful
- Grabbing data:
- Windows: see the Agilent web site I guess
- Linux: see this wiki page about installing agetwf (or install c_scan for more complex acquisition)
Tektronix MSO4034 Mixed Signal Oscilloscope
Tektronix MSO4034 mixed signal oscilloscope
- 4 analogue channels
- 16 digital channels
- 350MHz analogue bandwidth
- 2.5GSa/s
- 10Mpts waveform memory
- Location: Tower 201 (Applied Optics Main Lab)
- Contact: Steve Sharples
- Extra info:
- This has lots of bit with it, for the digital inputs, in addition to the usual manuals, installation CDs etc. Keep them all in the supplied bag and don't lose them
- Grabbing data:
- Windows: see the Tek web site I guess, or the installation CD
- Linux: see this wiki page about installing tgetwf (or install c_scan for more complex acquisition)
Laser Beam Profiler
Newport LBP-2-USB laser beam profiler
- Location: Tower 201
- Contact: Steve Sharples or Richard Smith
- Extra info:
- Runs under Windows XP
- Installation:
- Install software first
- Plug profiler into USB dongle
- Plug PSU brick into USB dongle
- Plug PSU brick into AC adapter (has US plug) and turn on mains
- Plug USB dongle into PC
Optical (Thermal) Power Meter
Gentec XLP-12 Thermopile-based optical power meter
- Location: usually Laser Ultrasound Labs (303-307). Possibly 201.
- Contact: Steve Sharples or whoever's experiment it's sat on
- Extra info:
- Sensitivity ~1mW to ~2W
- Works fine with mode-locked (e.g. femtosecond), Q-switched (Nd:YAG) and CW lasers (long time constant)
High Frequency Lock-in Amplifier
SR844 high frequency lock-in amplifier
- 25 kHz to 200 MHz frequency range
- 80 dB dynamic reserve
- Time constants from 100 µs to 30 ks (6, 12, 18 or 24 dB/oct rolloff)
- "No Time Constant" mode (10 to 20 µs update rate)
- Auto-gain, -phase, -reserve and -offset
- Internal or external reference
- Two 16-bit DACs and ADCs
- GPIB and RS-232 interfaces
- Location: usually Tower 304 (Ultrafast Lab)
- Contact: Richard Smith
- Extra info:
Ultrasonic Pulser-Receiver
Olympus (formerly Panametrics) 5072PR Ultrasonic Pulser-Receiver
- 35MHz bandwidth
- Spike excitation
- Location: CBS
- Contact: Melissa Mathers
- Extra info:
Dell 12" Laptop
- Standard UoN "PC Contract" Notebook
- Core 2 Duo CPU
- 2GB memory
- Docking station contains DVD RW (no DVD on laptop itself)
- WiFi, ethernet and modem
- SD card reader
- Windows XP SP3
- MS Office 2003 SP3
- Location: Tower - see Steve (or you should already know)
- Contact: Steve Sharples
- Extra info:
- Kensington lock should be used when left around the lab
- Bag and USB mouse available
- Set up with static (optics) IP on ethernet, and DHCP (roaming/UoN) on WiFi
Apple Macbook Laptop - cracked screen
Apple Macbook laptop, 1.8GHz Core 2 Duo processor. Has a cracked screen, making it pretty much unusable as a laptop. Now pensioned off to desktop duties.
- Apple Keynote: presentations
- Apple Pages: word processor
- MS Office 2003 for Mac (runs slow as it's the PowerPC version and runs under interpreter)
- QuickTime Pro: encodes movies and animations (possibly the most useful thing it does nowadays)
- Location: Tower 305 (Laser Ultrasound Labs foyer)
- Contact: Steve Sharples
Local Expertise
This section to be filled in another day.
External Facilities
Ground floor workshop
Physics fabrication and coating facilities
Talk to Teti Stratoudaki or Jing Zhang